Worcester Bosch Greenstar Intelligent Filling System (106HP)

£ 55.25INC VAT

Add to basket for...

Worcester Bosch Greenstar Intelligent Filling System (106HP)

All Boilers and Boiler Accessories must be installed by a Qualified Gas Safe Registered professional.

Intelligent software ensures the Greenstar 8000 Lifestyle range of boilers maintain optimum pressure. If the system pressure becomes low the software allows the internal filling valve to automatically fill the heating system. Once optimum pressure has been reached, this function will automatically stop and close the integrated filling valve. Also prevents the boiler from over-filling and will alert the customer if the heating system is losing too much pressure, reducing the need for unnecessary call-outs.

  • Provides Care-Free Heating & Hot Water
  • Reduces the Need for Pressure-Related Calls
  • Recognises Significant Leaks in the System

More Info

View all: Worcester Bosch Flues & Boiler Accessories

£55.25INC VAT

Add to basket for...

Add to saved list...

Save
Rated 3 out of 5 by from Need to read instructions The other 2 reviews slate this product, however I think it maybe they don’t know how it works and probably haven’t read the instructions. This will not just keep filling system if there is a leak. It will ‘top up’ pressure 5 times in a set period then shut off as it detects a leak. When installing, the system needs to be filled using the manual bypass on the link. The review that says it keeps going off and ‘doesn’t work’ are missing the point that their system has a major leak and this needs to be fixed. A sealed heating system should need topping up no more than 3-4 times a year at most. If the system is sound then this intelligent link is fine to use. By keep topping up with fresh water you will cause massive corrosion problems on the radiators which will either burst or cause blocked heat exchangers on boiler - whichever comes first
Date published: 2021-02-06
Rated 1 out of 5 by from Heating Engineer Absolute rubbish. If you have a leak it would keep filling the system. When fitted it wouldnt put enough pressure in to activate the pressure sensor. cost me money putting it in then taking it out.
Date published: 2021-01-16
Rated 1 out of 5 by from Does not work This was supposed to fix occasional low pressure problems. But it has made them worse since it does not work, and now when we have low pressure I cannot even manually add pressure without a callout So to is worse than useless Fitted to a new greenstar 8000 life This stupid gadget has cost me hundreds of pounds in plumbers fees and several days without hot water or heating.
Date published: 2020-10-29
  • y_2021, m_11, d_30, h_19
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.20
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_GB, sid_106HP, prod, sort_[SortEntry(order=FEATURED, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_screwfix
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 58ms
  • REVIEWS, PRODUCT

Fitting instructions

My fitter came round to fit this but could not tell from the booklet where to connect it to the boiler
Asked by: Faggy1
Your need to enable the device in the software to tell the boiler it has been connected. Confirm whether the installer has completed the set up
Answered by: Mark1959
Date published: 2021-11-13

Does this item need to be fitted by Corgi registered fitter

Asked by: Avlon
No such thing as a corgi registered fitter any more but you would be best using a Worcester trained engineer visit the Worcester Bosch website to find one local to you.
Answered by: derek2
Date published: 2021-06-26

How can I tell if this is installed and working?

On my new WB greenstar 8000 35kw
Asked by: AngusF
You could try bleeding your radiators around the house in order to lose a bit of pressure from your system. If you have one of these installed then it will top the pressure up automatically.
Answered by: Bnylk
Date published: 2020-03-27
  • y_2021, m_11, d_29, h_18CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.20
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_3
  • loc_en_GB, sid_106HP, prod, sort_[SortEntry(order=LOCALE, direction=DESCENDING), SortEntry(order=FEATURED, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_screwfix
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 15ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: BV SEO Content for this product did not include verbose reviews.;
Specification
Boiler Accessory Type Filling Loops
Brand Worcester Bosch
Manufacturer Guarantee 1 Year Guarantee
Pack Size 1
Pieces in Pack/Case 1
Product Type Greenstar Intelligent Filling System