type of sensors compatibulity
Can the sensor type be changed from 10 ohms sensor to 100 ohm sensor? some programmer allow you to select between the 2?
Asked by: calum1234
Hi there , our controller does not support the 100K ohm sensor type it does support 10K and 12K ohm sensor.
Answered by: Klima Underfloor Heating
Date published: 2022-02-19
Is this compatible with other heat mats?
Is this compatible with other heat mat products? I have a customer who currently has a thermostat that is faulty, will this be able to be used as a replacement model?
Asked by: Rjo3089511
Hi there , Yes it will be as long as you use OUR floor sensor provided with the controller.
Answered by: Klima Underfloor Heating
Date published: 2021-09-13
Will this fit one side of a dual metal backbox next to FCU
Planning to have FCU on one side of dual galvanised back box, and themostat/controller on the other.
Will this fit next to a standard FCU in the other side? [i.e. does it overlap beyond the limits of a standard single accessory?]
Asked by: tonyt
The controller fits into a standard lighting backing box, minimum 48mm deep. You will have to consult your electrician if your wanting to use any thing out with this.
Answered by: Klima Underfloor Heating
Date published: 2021-11-06
Installing the Klina Intelligent control
on the diagram, it does not explain if terminal 1 or 4 is for the life from the heating wire, or does it not matter
Asked by: pjt1863
The wires have no polarity on them so the live heating wire can be wired into terminal 1 or 4 , same with the negative heating wire can be wired into terminal 1 or 4.
Answered by: Klima Underfloor Heating
Date published: 2021-04-13