British General Fortress 22-Module 12-Way Populated … (7300G)

£ 95.39INC VAT

Add to basket for...

British General Fortress 22-Module 12-Way Populated Dual RCD Consumer Unit (7300G)

Fully populated, 12-way dual RCD, insulated metal consumer unit. Flexible busbar.

  • 100A Mains Switch
  • 2 x Type AC 63A 30mA RCDs
  • 12 x Type B MCBs (3 x 6A, 1 x 10A, 2 x 16A, 4 x 32A, 1 x 40A & 1 x 50A)
  • 4 Blanks
  • Flexible Busbar
  • DIN Rail Supplied
  • Top, Bottom, Side & Rear Cable Entry Points
  • Fitted Spirit Level

More Info

View all: British General Consumer Units

£95.39INC VAT

Add to basket for...

Add to saved list...

Save
Rated 5 out of 5 by from Split consumer unit Good product, but would always advice rcbo,saves a lot of running back with nuisance tripping.
Date published: 2021-09-09
Rated 4 out of 5 by from Ideal RCD consumer unit I've used this product before and I am totally confident about its performance. I was also satisfied with the price, considering that it fully held all the attributed features. I definitely will recommend it to anybody looking for something similar.
Date published: 2021-06-10
Rated 5 out of 5 by from Great price Great price and quick to arrive. Really good on price and easy to deal with.
Date published: 2021-05-14
Rated 5 out of 5 by from Great quality and value board Good quality and great price on this electric consumer board. Easy to install and instructions clear. Would highly recommend
Date published: 2021-02-22
  • y_2021, m_9, d_20, h_20
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.19
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_25
  • loc_en_GB, sid_7300G, prod, sort_[SortEntry(order=FEATURED, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_screwfix
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 23ms
  • REVIEWS, PRODUCT

Has the board got a fully floating busbar. i.e. can the main switch be positioned on LHS and can a non RCD MCB be installed before any of the 2 RCD's

Asked by: ChrisDD
Hi ChrisDD, The main issue you will have with trying to move the main switch to the left is that the RCDs are specifically polarised to have the outgoing Live to their left side, so you would need to be linking all the way across the board to power the far RCD, then have its devices coming back towards the near one, which is highly impractical. As for High Integrity ways, yes you can have up to 3 MCBs before the first RCD in the pre-installed configuration (with the main switch on the right).
Answered by: Nexus Technical Team
Date published: 2021-09-10

Can the blanks be populated with MCBs?

Asked by: Karlton
Hi Karlton, Yes, the blanks are simply there to fill in the unused ways until further MCBs are needed in the board.
Answered by: Nexus Technical Team
Date published: 2021-08-25

Is this a High Integrity CU as per desciption, or non-High Integrity as per spec?

Is this a High Integrity CU as per desciption, or non-High Integrity as per spec?
Asked by: Mikexx
Hi Mikexx, All of the BG Dual RCD boards can be installed with up to 3 High Integrity ways running directly off the main switch, but as this is not a requirement the board can be said to be both High Integrity and non-High Integrity until it has been installed.
Answered by: Nexus Technical Team
Date published: 2021-08-06

Is it complaint to BS7671 regulation 2020?

Asked by: Olgita
Hi Olgita, Our consumer units and devices are compliant to all relevant manufacturer requirements from all applicable standards.
Answered by: Nexus Technical Team
Date published: 2021-08-08

If I need one more 6A MCB, can I use 10A MCB instead or I need to order another 6A MCB? What's the model you recommend if I need to add another 6A MCB?

Asked by: MartinHu
Hi MartinHu, If the circuit cabling is rated to cope with 10A then you could use a 10A breaker, but if it is not then you should definitely stick with a 6A one [British General 6A SP Type B MCB (61373)].
Answered by: Nexus Technical Team
Date published: 2021-04-06
  • y_2021, m_9, d_20, h_20CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.19
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_21
  • loc_en_GB, sid_7300G, prod, sort_[SortEntry(order=LOCALE, direction=DESCENDING), SortEntry(order=FEATURED, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_screwfix
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 37ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: BV SEO Content for this product did not include verbose reviews.;
Specification
Brand British General
Cable Entry Points Top, Bottom, Side & Rear
Construction Material (Electrical) Steel
Consumer Unit Type Dual RCD
CSU Populated/Unpopulated Populated
Current Rating 100 A
Fixings Supplied Fixings Not Supplied
Integrity Non High Integrity
IP Rating IP2XC
Manufacturer Guarantee 10 Year Manufacturer's Guarantee (T&Cs Apply)
MCBs Supplied MCB
Model Name Fortress
Model No CFDP16616
No. of MCBs Supplied 12 x Type B MCBs (3 x 6A, 1 x 10A, 2 x 16A, 4 x 32A, 1 x 40A & 1 x 50A)
No. of Populated Ways 12
No. of RCBOs Supplied 0 x RCBOs
No. of RCDs Supplied 2 x Type AC 63A 30mA RCDs
No. of SPDs Supplied 0 x SPDs
Pack Size 1
Pieces in Pack/Case 1
Power Voltage Supply 230 V
Product Depth 155 mm
Product Height 231 mm
Product Type Consumer Unit
Product Width 496 mm
RCBOs Supplied No RCBOs Supplied
RCDs Supplied RCD
SPDs Supplied No SPDs Supplied
Total No. Module Spaces When Empty 22
Total Product Weight 6.4 kg
Way 12 Way

Product contents

Enclosure, main switch, RCDs (2), MCBs (11), busbar, cables and labels.