Browse store

Honeywell T6360B Room Thermostat (26159)

Dual diaphragm sensing element. Building Regulations compliant.

  • 3-Wire Installation
  • Heat Anticipator for Close Temperature Control
  • Indicator Lamp
  • For Use with Surface or Switch Mounting
  • Energy Saving Trust Approved
  • ERP Control Class: I

More Info

£26.99INC VAT

Add to basket for...

Rated 4.7 out of 5 by 38 reviewers.
  • 2016-07-25 T14:32:59.097-05:00
  • bvseo_lps, prod_bvrr, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasreviews, tv_38, tr_38
  • loc_en_US, sid_26159, prod, sort_default

Add to saved list...

Save
Rated 5 out of 5 by Honeywell An excellent thermostat and simple to fit if you're using it to replace the same model. Just three wires to connect in exactly the same way so the whole job only took about fifteen minutes. The old one still worked despite being over twenty years old but the new one looks fresher and has the handy indicator light. 21 Apr 2016
Rated 5 out of 5 by Perfectly simple Bought to replace an existing Honeywell thermostat. The last one was only replaced as the dial cracked and would not grip the internal parts. The light / neon tells you its calling for heat, which is a handy function. Simple three wire connection - Live Neutral and Switched Live 14 Apr 2016
Rated 5 out of 5 by Honeywell thermostat Dependable bit of kit ! Easy to follow wiring diagram, simple enough to install! 4 Apr 2016
Rated 5 out of 5 by Excellent product Bought thermostat to control a lot wattage electric panel radiator. Very easy to install. Works very well as you would expect, and ensures room does not get overheated. Cannot really comment on reliability as only just installed. 21 Mar 2016
  • 2016-07-25 T14:32:59.097-05:00
  • bvseo_lps, prod_bvrr, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasreviews, tv_38, tr_38
  • loc_en_US, sid_26159, prod, sort_default
Page : 2 3 next>
5 Questions  5 Answers

Screwfix Q&A

Ask your questions. Share your answers.

 
 
« Back
 
 
Search:
Sort by:
I replaced an old Sunvic with this and very happy. Wiring was the same so nothing to mess up. It works great and looks good on the wall but the LED indicator doesn't work. I returned it and swapped for another one and it's the same thing. Any ideas?
3 May 2016
Customer avatar
by
Surbiton
Read all my Q&A
, DIY
0points
0out of 0found this question helpful.
Was this helpful?Yes0No0
my old thermostat has 3 wires , red, yellow and blue..the earth has been cut back to the grey insulation
i can see the red is live feed and when the thermostat clicks on the red and yellow are live
so the yellow must be the feed to the boiler
the blue i assume is neutral
the terminal numbers on my old honeywell are
1 red
3 yellow
4 blue
this is in a straight line from one end
is this the correct connection to this newer honeywell
11 Jan 2016
Customer avatar
by
cornwall
Read all my Q&A
, DIY
0points
0out of 0found this question helpful.
Was this helpful?Yes0No0

Answers

Answer: 
Hello Weeee,

Please can you seek professional guidance relating to your query.

Hope this helps.
29 Mar 2016
0points
0of 0found this answer helpful.
Was this helpful?Yes0No0

Best answer
Answer: 
Hello, if your old thermostat is 1,3,4 you just connect the wires to this in the same way 1,3,4. This can also be connected 1,2,4 for systems with higher amperage (it explains it in the literature). But for you just ignore the '2'.
4 May 2016
Customer avatar
by
Surbiton
Read all my Q&A
, DIY
+2points
2of 2found this answer helpful.
Was this helpful?Yes2No0
9 Dec 2015
Customer avatar
by
Worcs
Read all my Q&A
, DIY
0points
0out of 0found this question helpful.
Was this helpful?Yes0No0

Answers

Answer: 
Hello Bellaboosh,

Please can you seek professional guidance relating to your query.

Hope this helps.
29 Mar 2016
0points
0of 0found this answer helpful.
Was this helpful?Yes0No0
28 Oct 2015
Customer avatar
by
Uxbridge
Read all my Q&A
, DIY
0points
0out of 0found this question helpful.
Was this helpful?Yes0No0

Answers

Answer: 
Hello John961,

Please can you seek professional guidance relating to your query.

Hope this helps.
29 Mar 2016
-2points
0of 2found this answer helpful.
Was this helpful?Yes0No2
17 Oct 2015
Customer avatar
by
bognor regis
Read all my Q&A
, DIY
0points
0out of 0found this question helpful.
Was this helpful?Yes0No0

Answers

Answer: 
Hello Fp12,

Please can you seek professional guidance relating to your query.

Hope this helps.
29 Mar 2016
-5points
1of 7found this answer helpful.
Was this helpful?Yes1No6
1 of 1
  • 2016-07-25 T14:30:52.114-05:00
  • bvseo_lps, prod_bvqa, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasquestionsanswers
  • loc_en_US, sid_26159, prod, sort_default
1 of 1
Specification
Brand Honeywell
Installation Type 3-Wire Installation
IP Rating IP30
Manufacturing Standards Building Regs Compliant, Conforms to 89/336/EEC & 73/23/EEC
Model No T6360B
Pack Size 1
Pieces in Pack/Case 1
Product Depth 37 mm
Product Height 84 mm
Product Type Room Thermostat
Product Width 84 mm
Switch Type SPST
Temperature Range 10-30 °C
Total Product Weight 0.14 kg

Switch/contact rating: SPST. IP30. 10A. Temp. range: 10°-30°C. H x W x D: 84 x 84 x 37mm.

Downloads

Instruction Manual