Browse store

FloPlast Push-Fit Air Admittance Valve Grey AF110 (78150)

Allows the free entry of air into the sanitary pipework system without the foul gases escaping into the building. Avoids the need to penetrate outer roof shell. It is recommended that air admittance valves are not used externally as environmental debris will affect the air tightness performance of the valve. Push-fit connection. Remove seal from 110mm push-fit for 82mm solvent connection. Tested and approved for use in installation varying between -20° and +60°C (no insulation required). can be installed below the flood level of connected appliances. FloPlast are the first company in the world to be awarded the Kitemark for Air Admittance Valves. Licence number KM512474.

More Info

£23.19INC VAT

Add to basket for...

Rated 4.8 out of 5 by 22 reviewers.
  • 2016-05-29 T10:39:42.032-05:00
  • bvseo_lps, prod_bvrr, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasreviews, tv_22, tr_22
  • loc_en_US, sid_78150, prod, sort_default

Add to saved list...

Save
Rated 5 out of 5 by AAV Great product. In stock when other places struggling. Being push fit allows it to be removed too for rodding access if ever needed. Also allows for installation below spillover level so neater for hiding it with boxing etc. 22 May 2016
Rated 4 out of 5 by good quality Good quality item. No more bad smells (unlike the old one!). 28 Jan 2016
Rated 5 out of 5 by FloPlast air admittance valve Good quality product. Easy to fit using washing up liquid to lubricate the seal first. Fixed the bad smell problem I had with the old valve. 12 Jan 2016
Rated 4 out of 5 by very easy to fit, job done no nasty smells, does what it is supposed to do, job done 3 Dec 2015
  • 2016-05-29 T10:39:42.032-05:00
  • bvseo_lps, prod_bvrr, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasreviews, tv_22, tr_22
  • loc_en_US, sid_78150, prod, sort_default
Page : 2 next>
6 Questions  7 Answers

Screwfix Q&A

Ask your questions. Share your answers.

 
 
« Back
 
 
Search:
Sort by:
24 May 2016
Customer avatar
by
Skeg
Read all my Q&A
, Builder/Multi Trade
0points
0out of 0found this question helpful.
Was this helpful?Yes0No0

Answers

Answer: 
No, the AF110 is for internal use only. The AX110 is for external use.
26 May 2016
0points
0of 0found this answer helpful.
Was this helpful?Yes0No0
 
1 Answer

Fitting

can the AAV be fitted either horazontally or vertically?
12 May 2016
Customer avatar
by
Norwich
Read all my Q&A
, DIY
0points
0out of 0found this question helpful.
Was this helpful?Yes0No0

Answers

Answer: 
The AAV can only be installed vertically.
13 May 2016
0points
0of 0found this answer helpful.
Was this helpful?Yes0No0
 
1 Answer

How does it fit?

When the valve is pushed in, how far down should it go? Is there a diagram which will show this? Mine seems rather tight and won't push all the way down.
25 Feb 2016
Customer avatar
by
Saltash
Read all my Q&A
, Other Trade
+1point
1out of 1found this question helpful.
Was this helpful?Yes1No0

Answers

Answer: 
All of the rubber seal at the bottom of the air valve should push into the soil pipe which is approx 50mm. You can use silicone lubricant to assist with the install.
26 Feb 2016
0points
0of 0found this answer helpful.
Was this helpful?Yes0No0
 
2 Answers

Use of AA valve

We live in a bungalow which has one toilet. We are knocking this thro to join with the bathroom. The waste from both the bath and basin go directly out thro the external wall along with the cistern overflow. I would like to remove the internal soil stack which has only the WC feeding into it and replace with this valve. are there any 'do's and 'dont's involved in doing this. Thanks for any advice. Graham
25 Jan 2016
Customer avatar
by
Clacton on Sea
Read all my Q&A
, DIY
+1point
1out of 1found this question helpful.
Was this helpful?Yes1No0

Answers

Answer: 
I contacted the Tech department at Flo-pas re my question as requested. Very helpful guy went through a few things and provided it is situated at least 200mm above waste entry no probs.
27 Jan 2016
Customer avatar
by
Clacton on Sea
Read all my Q&A
, DIY
+1point
1of 1found this answer helpful.
Was this helpful?Yes1No0

Best answer
Answer: 
This is a technical product and we would need to ask further questions please contact us on 01795 431731. Regards Craig Allen.
27 Jan 2016
+1point
1of 1found this answer helpful.
Was this helpful?Yes1No0
Hi there.

I only have one soil pipe on my property which feeds 2 toilets one upstairs and one down. I'm currently planning a rear extension and rather than venting the soil pipe through the roof I plan on venting it in the extension roof space however I have read that the pipe also has to be vented else where along the line is this correct or am I okay to use an AAV in this instance?

Thanks.
7 Nov 2015
Customer avatar
by
stoke
Read all my Q&A
, DIY
0points
0out of 0found this question helpful.
Was this helpful?Yes0No0

Answers

Answer: 
A single AAV would be permissible in these conditions unless you are going to a cess pit, or if you are in a row of properties and none of them have an open vent.
9 Nov 2015
+2points
2of 2found this answer helpful.
Was this helpful?Yes2No0
Page : 2 next >>
  • 2016-05-29 T10:36:55.145-05:00
  • bvseo_lps, prod_bvqa, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasquestionsanswers
  • loc_en_US, sid_78150, prod, sort_default
Page : 2 next >>
Specification
Brand FloPlast
Colour Grey
Connection Type Push-Fit
Manufacturer Guarantee 2 years
Manufacturing Standards EN 12380: 2002
Model No AF110G
Pack Size 1
Pieces in Pack/Case 1
Product Diameter 110 mm
Product Height 120 mm
Product Type Air Admittance Valve
Total Product Weight 0.163 kg