FloPlast AF110G Push-Fit Air Admittance Valve Grey (78150)

Allows the free entry of air into the sanitary pipework system without the foul gases escaping into the building. Avoids the need to penetrate outer roof shell. It is recommended that air admittance valves are not used externally as environmental debris will affect the air tightness performance of the valve. Push-fit connection. Remove seal from 110mm push-fit for 82mm solvent connection. Tested and approved for use in installation varying between -20° and +60°C (no insulation required). can be installed below the flood level of connected appliances. FloPlast are the first company in the world to be awarded the Kitemark for Air Admittance Valves.

More Info

£22.99INC VAT

Add to basket for...

FloPlast AF110G Push-Fit Air Admittance Valve Grey is rated 4.8 out of 5 by 28.
  • y_2017, m_8, d_14, h_3
  • bvseo_bulk, prod_bvrr, vn_bulk_1.0.0-hotfix-1
  • cp_1, bvpage1
  • co_hasreviews, tv_1, tr_27
  • loc_en_GB, sid_78150, prod, sort_[SortEntry(order=FEATURED, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_screwfix

Add to saved list...

Save
Rated 5 out of 5 by from Air Vent Existing Durgo Air Valve was letting smells through in hot weather, replaced with Floplast and problem solved.
Date published: 2017-08-10
Rated 5 out of 5 by from Ideal Following issues with toilet flush but water emptying away very slowly following a new washing machine be being install Plumber called and recommended we replaced our standard inspection dap with a vent one so far so good all is working well
Date published: 2017-05-16
Rated 4 out of 5 by from FloPlas air admittance valve Easy to fit and allowed me to get rid of the soil pipe in the bathroom so the whole room looks better after the refit. Not a hint of a smell so I hope its working.
Date published: 2017-03-29
Rated 5 out of 5 by from Air Admittance valve? How do you review an air admittance valve. It just sits there and does nothing for 99.999% of its time. No smells to report so I suppose that means it's ok. I can say it was easy to fit and looks the part.
Date published: 2017-02-16
  • y_2017, m_8, d_14, h_3
  • bvseo_bulk, prod_bvrr, vn_bulk_1.0.0-hotfix-1
  • cp_1, bvpage1
  • co_hasreviews, tv_1, tr_27
  • loc_en_GB, sid_78150, prod, sort_[SortEntry(order=FEATURED, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_screwfix

How can it be fitted below highest overflow level?

I am intrigued, as I would love to fit one inside the sink cabinet, 200mm above highest wet entry to 4" soil pipe. What feature has been added to allow this AAV to be below spill-over level?
Asked by: PhilipCC
FloPlast air admittance valves have an A1 rating which means that they can be installed below the flood level of connecting appliances. All you need to ensure is that the air admittance valve is at least 200mm above the highest wet entry point going into the soil stack that it is being fitted onto.
Answered by: FloPlast Ltd Tech Team
Date published: 2017-07-21

can this be fitted at an angle?

We have recently discovered that the builders of our 4 year old flat have not fitted this valve to the top of the soil pipe within the loft space. The pipe is roughly at a 45 degree angle. Will the valve still work? Thanks
Asked by: chrisj55
No, the air admittance valve must be installed up right and is unlikely to work in any other position.
Answered by: FloPlast Ltd Tech Team
Date published: 2017-07-13

If this can be fitted below the flood level of connected appliances what is minimum height that vent pipe needs to be from the floor?

Asked by: Terrysevenoakes
The air admittance valve needs to be installed a minimum of 200mm above the highest wet entry point connecting into the soil stack.
Answered by: FloPlast Ltd Tech Team
Date published: 2017-03-05

Can this be used on a property that uses an underground septic tank?

Asked by: Iwan
The AF110 can only be used on a property with a septic tank if there is another open vent pipe for the septic tank.
Answered by: FloPlast Ltd Tech Team
Date published: 2017-03-10

1960's Stack Pipe

I am looking at using the Floplast AAV internally in a 1960's soil pipe. Can I fit the AAV directly into the soil pipe or will I need an adapter?
Asked by: Gorilaz
Yes, the AF110 should fit directly onto the existing 1960's soil pipe.
Answered by: FloPlast Ltd Tech Team
Date published: 2017-06-10
  • y_2017, m_8, d_14, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_1.0.0-hotfix-1
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_11
  • loc_en_GB, sid_78150, prod, sort_[SortEntry(order=LOCALE, direction=DESCENDING), SortEntry(order=FEATURED, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_screwfix
Specification
Brand FloPlast
Colour Grey
Connection Type Push-Fit
Manufacturer Guarantee 2 Year Manufacturer's Guarantee (T&Cs Apply)
Model No AF110G
Pack Size 1
Pieces in Pack/Case 1
Product Diameter 110 mm
Product Height 120 mm
Product Type Air Admittance Valve
Total Product Weight 0.163 kg

EN 12380.