FloPlast AF110BL Push-Fit Air Admittance Valve Black (22674)

Allows the free entry of air into the sanitary pipework system without the foul gases escaping into the building. Avoids the need to penetrate outer roof shell. It is recommended that air admittance valves are not used externally as environmental debris will affect the air tightness performance of the valve. Push-fit connection. Remove seal from 110mm push-fit for 82mm solvent connection. Tested and approved for use in installation varying between -20° and +60°C (no insulation required). can be installed below the flood level of connected appliances. FloPlast are the first company in the world to be awarded the Kitemark for Air Admittance Valves.

More Info

£22.99INC VAT

Add to basket for...

FloPlast AF110BL Push-Fit Air Admittance Valve Black is rated 4.8 out of 5 by 9.
  • y_2017, m_3, d_25, h_2
  • bvseo_bulk, prod_bvrr, vn_bulk_1.0.0
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_9
  • loc_en_GB, sid_22674, prod, sort_[SortEntry(order=FEATURED, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_screwfix

Add to saved list...

Save
Rated 5 out of 5 by from super duper durgo valve Brilliant product at brilliant price. nice tight fit straight into soil pipe cheaper then buying a vented tile. works brilliant with no smell.
Date published: 2015-12-14
Rated 4 out of 5 by from Great Value Good quality easy to fit product. Actually using for a different application thaen its intended use but works well.
Date published: 2015-10-16
Rated 5 out of 5 by from easy to fit this is reasonable price and easy to fit to the system
Date published: 2015-06-11
Rated 5 out of 5 by from Easy to replace Durgo Valve The old valve, which the plumber installed, failed after 10 years. I purchased this Durgo valve from Screwfix and it was so easy to fix. It took more time to actually get to the old valve than it did to actually change it. Great product & great price.
Date published: 2015-05-21
  • y_2017, m_3, d_25, h_2
  • bvseo_bulk, prod_bvrr, vn_bulk_1.0.0
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_9
  • loc_en_GB, sid_22674, prod, sort_[SortEntry(order=FEATURED, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_screwfix

Does this valve need to be vented ( to the outside world ) or will it be okay to box it in?

Asked by: Geoff60371
The FloPlast air admittance valves can be boxed in however you will need to leave an access panel for maintenance purposes and also a small gap for air flow. A couple of drill holes into the boxing should be more than sufficient.
Answered by: FloPlast Ltd Tech Team
Date published: 2017-02-22

Please review your answer to previous question regarding Please clarify how far below highest overflow or water trap

Sepecification says: can be installed below flood level of connected appliances. Below means under highest wet entry point. You answer says: needs to be installed above highest wet entry point.
Asked by: Mike12345678
Being installed below the flood level of connected appliances will be the overflow level i.e, on a wash hand basin. The wet entry point will be the waste pipe taking the water away which is lower than the overflow level. The air admittance valves need to be installed a minimum of 200mm above the highest wet entry point into the soil stack. This may be below the overflow level of the connecting appliances.
Answered by: FloPlast Ltd Tech Team
Date published: 2017-03-14

Will this, or any other air admittance valve in your range push fit into a 82mm cast iron flue pipe? If not is there an alternative solution you could suggest? Many thanks.

Asked by: MickeyT
I am afraid that none of the FloPlast products would be suitable for connecting to a 82mm cast iron pipe.
Answered by: FloPlast Ltd Tech Team
Date published: 2017-03-10

I've just installed one of these. Fitted well however when I flush the toilet the flap doesn't lift or move but moves freely when pushed with fingers. Is this a faulty unit or is there not enough pressure build up with the flush to lift flap valve?

Fitted in loft, stack is above highest water level no back wash or blackage issues
Asked by: Johnnyq
The seals on the air admittance valve will only open if there is a build up on negative pressure within the system. If there is not enough negative pressure then the air admittance valve will not open.
Answered by: FloPlast Ltd Tech Team
Date published: 2017-03-13

can this be used to seal off an unused horizontal toilet waste pipe?

we had a separate toilet next to the bathroom and have taken the wall down to make the bathroom bigger. existing bathroom also had a toilet waste outlet so we no longer need the 'extra' one
Asked by: verab
The air admittance valve can be used however being installed horizontally it would never work and we could not guarantee that it would seal so may let smells out. It would also be an expensive way of blanking off the pipe as you could use an access cap or similar.
Answered by: FloPlast Ltd Tech Team
Date published: 2017-03-11
  • y_2017, m_3, d_24, h_20CST
  • bvseo_bulk, prod_bvqa, vn_bulk_1.0.0
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_6
  • loc_en_GB, sid_22674, prod, sort_[SortEntry(order=LOCALE, direction=DESCENDING), SortEntry(order=FEATURED, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_screwfix
Specification
Brand FloPlast
Colour Black
Connection Type Push-Fit
Manufacturer Guarantee 2 Year Manufacturer's Guarantee (T&Cs Apply)
Model No AF110BL
Pack Size 1
Pieces in Pack/Case 1
Product Diameter 110 mm
Product Height 120 mm
Product Type Air Admittance Valve
Total Product Weight 0.164 kg

EN 12380.